3 resultados para 6 dihydro 5

em Cochin University of Science


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Invertase was adsorbed onto micro-porous acid-activated montmorillonite clay (K-10) by two procedures, namely adsorption and covalent binding. The immobilized enzymes were characterized by XRD, surface area measurements and 27Al NMR. XRD measurements revealed an expansion of clay layers due to immobilization which suggests that intercalation had taken place. Surface area measurements also support this observation. 27Al NMR showed that interaction of enzyme with tetrahedral and octahedral Al changes with the immobilization procedure. Sucrose hydrolysis was performed in a batch reactor. The immobilized enzymes showed enhanced pH and thermal stabilities. Optimum pH and temperature were found to increase upon immobilization. The effectiveness factor (η) and Michaelis constant (Km) suggest that diffusional resistances play a major role in the reaction. The immobilized invertase could be stored in buffer of pH 5 and 6 at 5 °C without any significant loss in activity for 20 days.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Indium monofluoride was excited in a high-frequency discharge and the C-X system was photographed at a reciprocal dispersion of 0.3 AA mm-1 using a plane-grating spectrograph. Rotational analyses of the 0,0 1,0 2,2 3,3 4,4 2,4 3,5 4,6 and 5,7 bands have been carried out and the following molecular constants have been evaluated. Be'=0.2670(+or-3) cm-1, Be"=0.2628(+or-4) cm-1, alpha e'=0.0050(+or-4) cm-1, alpha e"=0.0020(+or-1) cm-1, De'=3.65(+or-5)*10-7 cm-1, De"=2.5(+or-3)*10-7 cm-1, beta e'=0.5(+or-2)*10-7 cm-1, beta e"=0.2(+or-1)*10-7 cm-1, re'=1.9672(+or-3) AA, re"=1.9853(+or-2) AA. The re" value agrees with the microwave absorption value 1.9854 AA.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, a novel fast method for modeling mammograms by deterministic fractal coding approach to detect the presence of microcalcifications, which are early signs of breast cancer, is presented. The modeled mammogram obtained using fractal encoding method is visually similar to the original image containing microcalcifications, and therefore, when it is taken out from the original mammogram, the presence of microcalcifications can be enhanced. The limitation of fractal image modeling is the tremendous time required for encoding. In the present work, instead of searching for a matching domain in the entire domain pool of the image, three methods based on mean and variance, dynamic range of the image blocks, and mass center features are used. This reduced the encoding time by a factor of 3, 89, and 13, respectively, in the three methods with respect to the conventional fractal image coding method with quad tree partitioning. The mammograms obtained from The Mammographic Image Analysis Society database (ground truth available) gave a total detection score of 87.6%, 87.6%, 90.5%, and 87.6%, for the conventional and the proposed three methods, respectively.